DocumentCode :
664394
Title :
Simultaneous measurement of multiple impulse responses with a single receiver
Author :
Mextorf, Henning ; Knochel, Reinhard
Author_Institution :
Univ. of Kiel, Kiel, Germany
fYear :
2013
fDate :
2-7 June 2013
Firstpage :
1
Lastpage :
3
Abstract :
This paper presents a method for the simultaneous measurement of multiple impulse responses with a single receiver. For UWB measurements multiple impulse responses are usually determined at different times. Here, an approach is investigated, which employs preferred pairs of maximum length sequences (m-sequences) having a low cross correlation function. Therefore, a measurement system is built capable of generating and sampling two m-sequences at 400Mb/s. Since the m-sequences are not decoupled perfectly, a method for the error correction is shown.
Keywords :
correlation methods; microwave measurement; radio receivers; signal sampling; UWB measurement; bit rate 400 Mbit/s; cross correlation function; error correction; m-sequence; maximum length sequence; multiple impulse response measurement; single receiver; Correlation; Error correction; Frequency measurement; Materials; Radar applications; Receivers; Time-domain analysis; UWB; m-sequence; maximum length sequence; time domain measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest (IMS), 2013 IEEE MTT-S International
Conference_Location :
Seattle, WA
ISSN :
0149-645X
Print_ISBN :
978-1-4673-6177-4
Type :
conf
DOI :
10.1109/MWSYM.2013.6697401
Filename :
6697401
Link To Document :
بازگشت