• DocumentCode
    664721
  • Title

    Respiration harmonics cancellation for Accurate Heart Rate measurement in non-contact vital sign detection

  • Author

    Jianxuan Tu ; Jenshan Lin

  • Author_Institution
    ECE Dept., Univ. of Florida, Gainesville, FL, USA
  • fYear
    2013
  • fDate
    2-7 June 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    Measuring the respiration rate (RR) and heart rate (HR) simultaneously in non-contact vital sign detection requires large dynamic range which is caused by large difference in respiratory and heart induced displacements. Generated by the demodulation method and displacements, the higher order harmonics of RR near HR might appear and cause error in HR measurement. A respiration harmonics cancellation method is proposed to eliminate the interference. Experiments are performed by a 5.8-GHz non-contact Doppler radar vital sign detection system with an S12 Any-Touch ECG-Accurate Heart Rate Monitor as the reference to verify the method. HR is measured by searching the highest peak within the typical HR range in the frequency spectrum. Results of HR measurement with and without the respiration harmonics cancellation method are compared. When the harmonics of the respiration signal are strong, using the respiration harmonics cancellation method reduces the average error from 15.9% to 3.2%.
  • Keywords
    Doppler radar; cardiovascular system; demodulation; electrocardiography; haemodynamics; harmonic analysis; interference suppression; medical signal detection; pneumodynamics; HR measurement; HR range; RR; S12 Any-Touch ECG-Accurate Heart Rate Monitor; accurate heart rate measurement; average error; demodulation method; frequency 5.8 GHz; frequency spectrum; heart induced displacement; higher order harmonics; interference elimination; large dynamic range; noncontact Doppler radar vital sign detection system; noncontact vital sign detection; respiration harmonics cancellation method; respiration rate; respiration signal; respiratory induced displacement; Demodulation; Doppler radar; Frequency measurement; Harmonic analysis; Heart rate; Interference; Power harmonic filters; arctangent demodulation; complex signal demodulation; heart rate (HR); non-contact Doppler radar vital sign detection; respiration harmonics cancellation; respiration rate (RR);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest (IMS), 2013 IEEE MTT-S International
  • Conference_Location
    Seattle, WA
  • ISSN
    0149-645X
  • Print_ISBN
    978-1-4673-6177-4
  • Type

    conf

  • DOI
    10.1109/MWSYM.2013.6697732
  • Filename
    6697732