DocumentCode
665948
Title
Two-phase interleaving configuration of the LLC resonant converter - Analysis and experimental evaluation
Author
Figge, H. ; Grote, T. ; Schafmeister, F. ; Frohleke, Norbert ; Bocker, Joachim
Author_Institution
New Technol., DELTA Energy Syst. (Germany) GmbH, Soest, Germany
fYear
2013
fDate
10-13 Nov. 2013
Firstpage
1392
Lastpage
1397
Abstract
The LLC resonant converter has become quite popular in recent years and is more and more used for DC-DC converters within cost effective as well as high performance power supplies. Since in case of high output power and low output voltage it is typically beneficial to use paralleled converters, this paper investigates the load sharing issue of two LLC converters connected in parallel and operated with interleaved driving signals. Value deviations of all the three passive components of the LLC resonant circuit are considered and the worst case scenarios are highlighted. Moreover a simple and practical solution to the load sharing issue applicable to a high power server PSU is presented, including measurements on a prototype to support the theoretical analysis.
Keywords
DC-DC power convertors; LC circuits; passive networks; phase convertors; resonant power convertors; DC-DC converter; LLC resonant converter; high performance power supply; high power server PSU; interleaved driving signal; load sharing; passive component; two-phase interleaving configuration; Damping; Integrated circuit modeling; Load modeling; RLC circuits; Rails; Steady-state; Switching frequency; Current Sharing; Interleaving; LLC; Resonant Converter; Steady-State;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics Society, IECON 2013 - 39th Annual Conference of the IEEE
Conference_Location
Vienna
ISSN
1553-572X
Type
conf
DOI
10.1109/IECON.2013.6699336
Filename
6699336
Link To Document