  • Abstract
    How does one directly assess the quality of a Rb atomic clock signal remotely and in real time? Typically, one monitors the clock´s 2nd harmonic signal, S2, which in the quasi-static approximation is a measure of the correction signal´s slope, dS1/dΔ. Unfortunately, in real vapor-cell clocks the quasi-static approximation is not valid, and the physics relating S2 to dS1/dΔ is complicated and not well understood. We have begun a series of studies aimed at elucidating the relationship between S2 and dS1/dΔ, and here we present our preliminary results.
  • Keywords
    atomic clocks; harmonics; rubidium; 2nd harmonic signal; Rb; Rb atomic clock signal; correction signal slope; error-signal quality; quasistatic approximation; vapor-cell clocks; Atom optics; Atomic clocks; Frequency modulation; Harmonic analysis; Microwave amplifiers; Optical pumping; Rabi resonance; Rb atomic clock; atomic clocks; frequency modulation; second harmonic; vapor-cell clock;