DocumentCode :
669259
Title :
Effective implementation of ring artifacts removal filters for synchrotron radiation microtomographic images
Author :
Brun, Francesco ; Accardo, Agostino ; Kourousias, George ; Dreossi, Diego ; Pugliese, Roberto
Author_Institution :
Dept. of Eng. & Archit., Univ. of Trieste, Trieste, Italy
fYear :
2013
fDate :
4-6 Sept. 2013
Firstpage :
672
Lastpage :
676
Abstract :
The presence of ring artifacts in X-ray computed microtomography affects the qualitative and quantitative analyses of the reconstructed images. Although digital image processing approaches to ring artifacts removal via direct filtering of the reconstructed images exist, in synchrotron radiation microtomography this issue is usually faced during the actual reconstruction process by de-striping the sinogram image. In this work different de-striping algorithms are discussed and preliminary compared using a suitably created test image as well as actual imaged data. Because of the increasing need for fast reconstruction workflows, details of the implementation and the related computational aspects are also considered. Moreover, the hardware and software solution developed and deployed for the SYRMEP (SYnchrotron Radiation for MEdical Physics) microtomographic beamline of the Italian synchrotron radiation facility (Elettra - Sincrotrone Trieste S.C.p.A) is presented. This solution is based on a highperformance computing (HPC) cluster with the Oracle Grid Engine distributed resource management (DRM) system and Python code that takes advantage of the NumPy and SciPy libraries. This work makes available high resolution test images as well as source code at: ulisse.elettra.trieste.it/uos/pore3d/ringrem.
Keywords :
computerised tomography; diagnostic radiography; filtering theory; image reconstruction; medical image processing; DRM; Italian synchrotron radiation facility; NumPy libraries; Oracle grid engine; Python code; SYRMEP microtomographic beamline; SciPy libraries; X-ray computed microtomography; digital image processing; direct image reconstruction filtering; distributed resource management system; high-performance computing cluster; ring artifacts removal filters; sinogram image de-striping; synchrotron radiation microtomographic images; synchrotron radiation-for-medical physics; Algorithm design and analysis; Image reconstruction; Rivers; Signal processing algorithms; Synchrotron radiation; Tomography; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image and Signal Processing and Analysis (ISPA), 2013 8th International Symposium on
Conference_Location :
Trieste
Type :
conf
DOI :
10.1109/ISPA.2013.6703823
Filename :
6703823
Link To Document :
بازگشت