DocumentCode
66961
Title
Detection of Partially Fallen-Out Magnetic Slot Wedges in Inverter-Fed AC Machines at Lower Load Conditions
Author
Stojcic, Goran ; Vasak, Mario ; Peric, Nebojsa ; Joksimovic, Gojko ; Wolbank, Thomas M.
Author_Institution
Dept. of Energy Syst. & Electr. Drives, Vienna Univ. of Technol., Vienna, Austria
Volume
50
Issue
2
fYear
2014
fDate
March-April 2014
Firstpage
1161
Lastpage
1167
Abstract
Electrical machines in the high-voltage class are usually designed with open stator slots. This wide open slots cause an increase of higher order harmonics, vibrations, noise, and temperature; thus, the machine efficiency is decreased. To counteract this disadvantage, magnetic slot wedges are applied. Due to the impact of high magnetic and mechanical forces, these wedges can fall out and may cause further serious damages. Up to now, reliable detection methods for single missing slot wedges are coupled with a disassembling of parts of the machine. In this paper, a method is investigated which provides the possibility of detection, based on the measurement of electrical terminal quantities only.
Keywords
AC machines; invertors; magnetic forces; magnetic sensors; stators; vibrations; electrical terminal measurement; high-voltage electrical machine; higher order harmonics; inverter-fed AC machine; magnetic force; mechanical force; open stator slot; partially fallen-out magnetic slot wedge detection; vibration; Current measurement; Inductance; Magnetic flux; Rotors; Stator windings; Transient analysis; AC machines; condition monitoring; fault detection; stator slot wedges; transient excitation;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2013.2275955
Filename
6573372
Link To Document