• DocumentCode
    674518
  • Title

    Toward temporal fiber

  • Author

    Ozon, Matthew ; Robini, Marc ; Croisille, Pierre ; Frindel, Carole ; Yue-Min Zhu

  • Author_Institution
    INSA Lyon, INSERM, CREATIS, Univ. Lyon 1, Lyon, France
  • fYear
    2013
  • fDate
    22-25 Sept. 2013
  • Firstpage
    567
  • Lastpage
    570
  • Abstract
    One of the next challenges of DTI in cardiac domain is to assess moving fibers. An important bottleneck is the acquisition time due to the angular resolution required to extract accurate myocardial fibers. Therefore, the creation of a method able to extract reliable fibers from low angular resolution is a key point to accelerate DTI acquisition, consequently a considerable step toward temporal fibers. In this study we introduce a graph-based method for fiber tracking and evaluate its performances.
  • Keywords
    biodiffusion; biomedical MRI; cardiology; feature extraction; graphs; muscle; DTI acquisition; acquisition time; angular resolution; cardiac domain; diffusion tensor imaging; fiber tracking; graph-based method; myocardial fiber extraction; temporal fiber; Convergence; Cooling; Diffusion tensor imaging; Heart; Myocardium; Reliability; Signal to noise ratio;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology Conference (CinC), 2013
  • Conference_Location
    Zaragoza
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-4799-0884-4
  • Type

    conf

  • Filename
    6713440