DocumentCode :
674639
Title :
Different definitions of complex fractionated atrial electrograms do not concur with the clinical perspective
Author :
Almeida, Tiago P. ; Salinet, Joao L. ; Chu, Gavin S. ; Ng, G. Andre ; Schlindwein, Fernando S.
Author_Institution :
Dept. of Eng., Univ. of Leicester, Leicester, UK
fYear :
2013
fDate :
22-25 Sept. 2013
Firstpage :
1055
Lastpage :
1058
Abstract :
Complex fractionated atrial electrograms (CFAEs) have been suggested as potential targets for ablation for persistent atrial fibrillation (AF), but there is no consensus on their definition. This study aimed to quantify the impact of different CFAE definitions on automated CFAE detection based on NavX criteria, and compare them with visual assessment. Baseline and post pulmonary vein isolation continuously-recorded bipolar electrograms obtained using a decapolar catheter placed into the coronary sinus from six persistent AF patients were analysed using different time-windows. Automatic CFAE detection algorithm based on selected negative deflections was developed. Three different CFAE definitions, as described in the literature, were evaluated, and electrograms were labelled as fractionated or non-fractionated according to each definition. Fractionation interval and CFAEmean were assessed based on each definition, followed by a blinded visual inspection of a clinician. The results show that the electrogram window size did not change overall CFAEmean. However, different CFAE definitions impacted fractionation significantly on both pre-/post-ablation groups. If automated algorithms are to be used in clinical practice, differences in CFAE definitions might have significant impact on CFAEs quantification.
Keywords :
blood vessels; diseases; electrocardiography; fractionation; medical signal processing; NavX criteria; automated CFAE detection; baseline pulmonary vein isolation; blinded visual inspection; clinical perspective; clinical practice; complex fractionated atrial electrograms; continuously-recorded bipolar electrograms; coronary sinus; decapolar catheter; electrogram window size; fractionation interval; persistent atrial fibrillation ablation; post pulmonary vein isolation; potential targets; time windows; visual assessment; Abstracts; Cardiology; Europe; MATLAB; Rhythm;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computing in Cardiology Conference (CinC), 2013
Conference_Location :
Zaragoza
ISSN :
2325-8861
Print_ISBN :
978-1-4799-0884-4
Type :
conf
Filename :
6713562
Link To Document :
بازگشت