• DocumentCode
    674652
  • Title

    Analysis of seismocardiogram capability for prediction of mild to moderate haemorrhage; Preliminary results

  • Author

    Tavakolian, Kouhyar ; Dumont, Guy A. ; Blaber, Andrew

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of British Columbia, Vancouver, BC, Canada
  • fYear
    2013
  • fDate
    22-25 Sept. 2013
  • Firstpage
    1107
  • Lastpage
    1110
  • Abstract
    Seismocardiogram (SCG) is proposed in this study to be used for earlier detection of hemorrhage and lower body negative pressure (LBNP) was used to create a hemodynamic response similar to hemorrhage. Echocardiogram measurements showed a maximal reduction of 23% in cardiac output. Analysis of left ventricular ejection time (LVET), derived from a seismocardiogram (SCG), demonstrated to be more sensitive in detection of early stage hemorrhage compared to pulse pressure and heart rate. LVET was significantly different between different stages of LBNP for thirty two subjects.
  • Keywords
    blood pressure measurement; echocardiography; medical disorders; LBNP; LVET analysis; early hemorrhage detection; early lower body negative pressure detection; echocardiogram measurements; heart rate; hemodynamic response; left ventricular ejection time analysis; maximal cardiac output reduction; mild haemorrhage prediction; moderate haemorrhage prediction; pulse pressure; seismocardiogram; Abstracts; Atmospheric measurements; Electrocardiography; Hemorrhaging; Monitoring; Particle measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology Conference (CinC), 2013
  • Conference_Location
    Zaragoza
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-4799-0884-4
  • Type

    conf

  • Filename
    6713575