Title :
On the Perturb-and-Observe and Incremental Conductance MPPT Methods for PV Systems
Author :
Sera, Dezso ; Mathe, Laszlo ; Kerekes, Tamas ; Spataru, S.V. ; Teodorescu, Remus
Author_Institution :
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
Abstract :
This paper presents a detailed analysis of the two most well-known hill-climbing maximum power point tracking (MPPT) algorithms: the perturb-and-observe (P&O) and incremental conductance (INC). The purpose of the analysis is to clarify some common misconceptions in the literature regarding these two trackers, therefore helping the selection process for a suitable MPPT for both researchers and industry. The two methods are thoroughly analyzed both from a mathematical and practical implementation point of view. Their mathematical analysis reveals that there is no difference between the two. This has been confirmed by experimental tests according to the EN 50530 standard, resulting in a deviation between their efficiencies of 0.13% in dynamic and as low as 0.02% under static conditions. The results show that despite the common opinion in the literature, the P&O and INC are equivalent.
Keywords :
electric admittance; mathematical analysis; maximum power point trackers; photovoltaic power systems; hill-climbing maximum power point tracking algorithms; incremental conductance MPPT methods; mathematical analysis; perturb-and-observe conductance MPPT methods; photovoltaic systems; Discrete implementation; incremental conductance (INC); maximum power point tracking (MPPT); perturb-and-observe (P&O); photovoltaic (PV) systems;
Journal_Title :
Photovoltaics, IEEE Journal of
DOI :
10.1109/JPHOTOV.2013.2261118