DocumentCode :
67859
Title :
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Author :
Yousefi, Rasoul ; Nourani, M. ; Ostadabbas, S. ; Panahi, Issa
Author_Institution :
Quality of Life Technol. Lab., Univ. of Texas at Dallas, Richardson, TX, USA
Volume :
18
Issue :
2
fYear :
2014
fDate :
Mar-14
Firstpage :
670
Lastpage :
681
Abstract :
The performance of portable and wearable biosensors is highly influenced by motion artifact. In this paper, a novel real-time adaptive algorithm is proposed for accurate motion-tolerant extraction of heart rate (HR) and pulse oximeter oxygen saturation (SpO2) from wearable photoplethysmographic (PPG) biosensors. The proposed algorithm removes motion artifact due to various sources including tissue effect and venous blood changes during body movements and provides noise-free PPG waveforms for further feature extraction. A two-stage normalized least mean square adaptive noise canceler is designed and validated using a novel synthetic reference signal at each stage. Evaluation of the proposed algorithm is done by Bland-Altman agreement and correlation analyses against reference HR from commercial ECG and SpO2 sensors during standing, walking, and running at different conditions for a single- and multisubject scenarios. Experimental results indicate high agreement and high correlation (more than 0.98 for HR and 0.7 for SpO2 extraction) between measurements by reference sensors and our algorithm.
Keywords :
biosensors; blood; blood vessels; chemical sensors; feature extraction; filtering theory; gait analysis; medical signal processing; oximetry; oxygen; photoplethysmography; portable instruments; real-time systems; signal denoising; Bland-Altman agreement; O2; SpO2 sensors; body movements; correlation analyses; feature extraction; heart rate extraction; motion artifact removal; motion-tolerant adaptive algorithm; noise-free PPG waveforms; portable biosensors; pulse oximeter oxygen saturation; real-time adaptive algorithm; running; standing; tissue effect; two-stage normalized least mean square adaptive noise canceler; venous blood changes; walking; wearable biosensors; wearable photoplethysmographic biosensors; Adaptive filter; motion artifact; noise reduction; photoplethysmography (PPG); pulse oximeter; wearable biosensor;
fLanguage :
English
Journal_Title :
Biomedical and Health Informatics, IEEE Journal of
Publisher :
ieee
ISSN :
2168-2194
Type :
jour
DOI :
10.1109/JBHI.2013.2264358
Filename :
6517455
Link To Document :
بازگشت