DocumentCode
682193
Title
Measurement and uncertainty evaluation for planar material´s shielding effectiveness with the flange coaxial system
Author
Cai Qing
Author_Institution
Sch. of Electron. Inf. & Electr. Eng., Shanghai Jiaotong Univ., Shanghai, China
Volume
1
fYear
2013
fDate
16-19 Aug. 2013
Firstpage
446
Lastpage
450
Abstract
Shielding effectiveness of material is important research topic to meet the requirement of electromagnetic compatibility. In this paper, measurement procedure and evaluation of uncertainty of shielding effectiveness to the material on flange coaxial system are introduced. The paper describes the calculation of SE from surface resistivity and gives different comparison data. The main sources that make up the whole uncertainty are proposed.
Keywords
flanges; magnetic shielding; measurement uncertainty; surface resistance; flange coaxial system; measurement uncertainty; planar material shielding effectiveness; surface resistivity; Electromagnetic shielding; Flanges; Frequency measurement; Materials; Measurement uncertainty; Signal generators; Uncertainty; flange coaxial; measurement uncertainty; shielding effectiveness; surface resistivity;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Measurement & Instruments (ICEMI), 2013 IEEE 11th International Conference on
Conference_Location
Harbin
Print_ISBN
978-1-4799-0757-1
Type
conf
DOI
10.1109/ICEMI.2013.6743030