DocumentCode :
683852
Title :
Partial discharge investigations on a high voltage generator cable insulation through TF method
Author :
Arumugam, Saravanakumar ; Gorchakov, S. ; Schoenemann, Thomas
Author_Institution :
Inst. of Electr. Power Eng., Univ. of Rostock, Rostock, Germany
fYear :
2013
fDate :
20-23 Oct. 2013
Firstpage :
1101
Lastpage :
1104
Abstract :
Partial discharge (PD) that occurs on the insulation of a high voltage (HV) generator bar has decisive influence over its operating condition and efficiency. So, it is vital to provide special attention while monitoring the PD activity of pertinent insulation arrangement. In particular, the occurrence of internal discharges that emerges due to micro-voids initiates PD which initially doesn´t pose an immediate threat. Nevertheless, the prolonged internal discharges might cause permanent damage to the localized site insulation. The high operating temperature, electrical discharges and other adverse operating conditions aggravate the ageing phenomena which might result in premature failure of the generator. The modern maintenance procedures include periodical visual inspection and dielectric tests. Additionally, PD based monitoring systems are also installed to measure the level of PD and analyze the trend followed over a period of time. However, it is quite important to analyze the PD data from every aspect to understand the underlying phenomena and exercise a better maintenance procedure. In this regard, the present study resolves the PD that evolves in the micro-voids of mica based insulation of a HV generator bar. The PD levels of insulation coated on HV generator arrangement is measured, recorded and their respective phase resolved PD pattern (PRPD) is analyzed. Later, the measured PD signals are transformed into frequency domain and the possibilities and status of the sample bar is analyzed.
Keywords :
bars; electric generators; failure analysis; fault diagnosis; frequency-domain analysis; maintenance engineering; mica; partial discharges; power cable insulation; HV generator arrangement; HV generator bar insulation; PD; PD activity monitoring; PD data; PD levels; PD-based monitoring systems; PRPD; TF method; dielectric test; electrical discharges; frequency domain; generator premature failure; high-voltage generator bar insulation; high-voltage generator cable insulation; internal discharge occurrence; localized site insulation; maintenance procedure; measured PD signals; mica-based insulation; microvoids; operating temperature; partial discharge investigation; periodical visual inspection; pertinent insulation arrangement; respective phase resolved PD pattern; Dielectric measurement; Dielectrics; Frequency measurement; Generators; Insulation; Partial discharges; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2013 IEEE Conference on
Conference_Location :
Shenzhen
Type :
conf
DOI :
10.1109/CEIDP.2013.6747088
Filename :
6747088
Link To Document :
بازگشت