    Preliminary study of bubble formation in vegetable oil filled power transformer

  • Author

    Perkasa, Caesar Y. ; Wijaya, Jaury ; Lelekakis, Nick ; Martin, Daniel

  • Author_Institution
    Centre for Power Transformer Monitoring, Diagnostics, & Life Manage., Monash Univ., Clayton, VIC, Australia
  • fYear
    2013
  • fDate
    20-23 Oct. 2013
  • Firstpage
    551
  • Lastpage
    554
  • Abstract
    This paper presents the work performed to date on investigating water bubble formation in transformer oil and cellulose insulation systems, and any impact that using a vegetable oil dielectric will have in contrast to standard mineral oil. It is important to understand this phenomenon because it can lead to the failure of a transformer on overload, when water suddenly migrates from the cellulose into the oil. The system used to investigate bubbling is presented in this paper along with a discussion on how bubbling occurs. The next step will be to re-perform this investigation using vegetable oil under a variety of different conditions.
  • Keywords
    bubbles; power transformer insulation; transformer oil; vegetable oils; water; cellulose insulation systems; mineral oil; power transformer; transformer oil; vegetable oil; water bubble formation; Mathematical model; Minerals; Oil insulation; Power transformer insulation; Windings;
  • fLanguage