Performance evaluation of the dual ring MAMMI breast PET
Author
Soriano, A. ; Sanchez, F. ; Carrilero, V. ; Pardo, Abelardo ; Vidal, L.F. ; Vazquez, Carlos ; Barbera, J. ; Seimetz, M. ; Rodriguez-Alvarez, M.J. ; Rigla, J.P. ; Moliner, L. ; Iborra, A. ; Hernandez, L. ; Gonzalez, A.J. ; Crespo, E. ; Conde, P. ; Bellido,
Author_Institution
Inst. of Instrum. for Mol. Imaging, UPV, Valencia, Spain
fYear
2013
fDate
Oct. 27 2013-Nov. 2 2013
Firstpage
1
Lastpage
4
Abstract
MAMMI is a dedicated breast positron emission tomograph (PET) based on monolythic LYSO crystals, with a transaxial field of view (FOV) of 170 mm. It has been upgraded by adding a second ring of detectors that extends the axial FOV from 40 mm to 94.4 mm, in order to improve its sensitivity and reduce the acquisition time. In this work we present the performance evaluation of the dual ring MAMMI breast PET and a discussion about the contribution of the addition of a second ring of detectors, the compensation of the detector blur and the increase of the scintillator thickness. Experimental measurements suggested on NEMA NU 4-2008 and NEMA NU 2-2007 have been conveniently adapted to the dimensions of the MAMMI. The addition of the second ring of detectors leads to a rise of the sensitivity from 1.8% to 3.6%. The spatial resolution at one-fourth of the axial FOV (1.5 mm axial, 1.6 mm tangential, 1.7 mm radial) is slightly better than that measured at the axial center (1.9 mm axial, 1.8 mm tangential and radial), because of the 14 mm gap in between detection rings. The results obtained after the evaluation reflect a substantial performance improvement, specially in the absolute sensitivity, because of the changes introduced in the MAMMI PET.
Keywords
image resolution; mammography; positron emission tomography; NEMA NU 2-2007; NEMA NU 4-2008; breast positron emission tomography; detection rings; detector blur compensation; dual ring MAMMI breast PET; mammography; molecular imaging; monolythic LYSO crystals; performance evaluation; scintillator thickness; sensitivity; spatial resolution; transaxial field of view; Breast; Detectors; Photonics; Positron emission tomography; Positrons; Sensitivity; Spatial resolution; Mammography; breast PET;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location
Seoul
Print_ISBN
978-1-4799-0533-1
Type
conf
DOI
10.1109/NSSMIC.2013.6829103
Filename
6829103
Link To Document