DocumentCode
687067
Title
A monolithic segmented germanium detector with highly integrated readout
Author
Rumaiz, Abdul K. ; Krings, T. ; Siddons, David P. ; Kuczewski, A.J. ; Protic, D. ; Ross, C. ; De Geronimo, G. ; Zhong, Z.
Author_Institution
Photon Sci. Directorate, Brookhaven Nat. Lab., Upton, NY, USA
fYear
2013
fDate
Oct. 27 2013-Nov. 2 2013
Firstpage
1
Lastpage
5
Abstract
We have constructed a pixelated germanium detector using a technique which has been shown to provide good isolation between adjacent pixels. In this work we present initial tests of the application of a low-noise CMOS ASIC to read out this detector. The detector has 64 pixels, each 0.5mm × 5mm, arranged as a series of strips. It is connected by wire-bonds to two 32-channel ASICs (Application-Specific Integrated Circuit) which provide a complete photon-counting chain for every channel. Since the size of the pixel array is no longer restricted by the difficulties of instrumenting large channel-count conventional electronics, this development will open up the possibility of even larger arrays, similar to those offered by silicon detectors.
Keywords
CMOS integrated circuits; application specific integrated circuits; germanium radiation detectors; nuclear electronics; readout electronics; 32-channel ASIC; Application-Specific Integrated Circuit; complete photon-counting chain; highly integrated readout; low-noise CMOS ASIC application; monolithic segmented germanium detector; pixelated germanium detector; Application specific integrated circuits; Arrays; Detectors; Germanium; Silicon; Strips;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location
Seoul
Print_ISBN
978-1-4799-0533-1
Type
conf
DOI
10.1109/NSSMIC.2013.6829507
Filename
6829507
Link To Document