DocumentCode :
687146
Title :
A balloon-borne measurement of high latitude atmospheric neutrons using a licaf neutron detector
Author :
Kole, Merlin ; Fukazawa, Yoshiaki ; Fukuda, Kenji ; Ishizu, Sumito ; Jackson, Michael ; Kamae, Tune ; Kawaguchi, Noriyuki ; Kawano, T. ; Kiss, M. ; Moretti, Elena ; Salinas, Maria Fernanda Munoz ; Pearce, Mark ; Rydstrom, Stefan ; Takahashi, Hiroki ; Yana
Author_Institution :
Dept. of Phys., KTH (R. Inst. of Technol.), Stockholm, Sweden
fYear :
2013
fDate :
Oct. 27 2013-Nov. 2 2013
Firstpage :
1
Lastpage :
8
Abstract :
PoGOLino is a scintillator-based neutron detector. Its main purpose is to provide data on the neutron flux in the upper stratosphere at high latitudes at thermal and non-thermal energies for the PoGOLite instrument. PoGOLite is a balloon borne hard X-ray polarimeter for which the main source of background stems from high energy neutrons. No measurements of the neutron environment for the planned flight latitude and altitude exist. Furthermore this neutron environment changes with altitude, latitude and solar activity, three variables that will vary throughout the PoGOLite flight. PoGOLino was developed to study the neutron environment and the influences from these three variables upon it. PoGOLino consists of two Europium doped Lithium Calcium Aluminium Fluoride (Eu:LiCAF) scintillators, each of which is sandwiched between 2 Bismuth Germanium Oxide (BGO) scintillating crystals, which serve to veto signals produced by gamma-rays and charged particles. This allows the neutron flux to be measured even in high radiation environments. Measurements of neutrons in two separate energy bands are achieved by placing one LiCAF detector inside a moderating polyethylene shield while the second detector remains unshielded. The PoGOLino instrument was launched on March 20th 2013 from the Esrange Space Center in Northern Sweden to an altitude of 30.9 km. A description of the detector design and read-out system is presented. A detailed set of simulations of the atmospheric neutron environment performed using both PLANETOCOSMICS and Geant4 will also be described. The comparison of the neutron flux measured during flight to predictions based on these simulations will be presented and the consequences for the PoGOLite background will be discussed.
Keywords :
cosmic ray neutrons; neutron flux; solar cosmic ray particles; solid scintillation detectors; Esrange Space Center; Geant4; LiCAF detector; LiCAF neutron detector; Northern Sweden; PLANETOCOSMICS; PoGOLino scintillator-based neutron detector; PoGOLite flight; PoGOLite instrument; atmospheric neutron environment; balloon-borne hard X-ray polarimeter; balloon-borne measurement; bismuth germanium oxide scintillating crystals; europium doped lithium calcium aluminium fluoride scintillators; flight altitude; flight latitude; gamma-rays; high latitude atmospheric neutrons; high radiation environments; neutron flux; read-out system; solar activity; Atmospheric measurements; Atmospheric modeling; Detectors; Instruments; Neutrons; Plastics; Terrestrial atmosphere; LiCAF; PoGOLino; PoGOLite; X-ray; atmospheric; balloon-borne; neutrons; polarimetry;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location :
Seoul
Print_ISBN :
978-1-4799-0533-1
Type :
conf
DOI :
10.1109/NSSMIC.2013.6829591
Filename :
6829591
Link To Document :
بازگشت