DocumentCode :
687240
Title :
Performance of clear fiber TOP detector
Author :
Kumogoshi, D. ; Han, Shuo ; Iijima, S. ; Ito, H. ; Kawai, Hiroyuki ; Kodama, Shinsuke ; Mase, Kenji
Author_Institution :
Grad. Sch. of Sci., Chiba Univ., Chiba, Japan
fYear :
2013
fDate :
Oct. 27 2013-Nov. 2 2013
Firstpage :
1
Lastpage :
3
Abstract :
Usual TOP (time of propagation) detectors have several disadvantages. We propose a new TOP detector which overcomes those by using clear fibers (these have high transparency than general optical fibers). We performed Monte Carlo simulations with Geant4 and tested a prototype with e+ of 0.7 to 1.0 GeV at SPring8 BR33LEP beam line. We propose this detector to E-36 experiment at J-PARC.
Keywords :
Cherenkov counters; Monte Carlo methods; photomultipliers; E-36 experiment; J-PARC; Monte Carlo simulations; beam line; clear fiber TOP detector; clear fibers; high transparency; optical fibers; photomultiplier tube; time of propagation detectors; Detectors; Monte Carlo methods; Optical fiber testing; Optical fibers; Photonics; Prototypes; Refractive index;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location :
Seoul
Print_ISBN :
978-1-4799-0533-1
Type :
conf
DOI :
10.1109/NSSMIC.2013.6829687
Filename :
6829687
Link To Document :
بازگشت