DocumentCode
690967
Title
Research on Data Consistency in Electric Field Measurement
Author
Wu Qi ; Yuan Haiwen ; Cui Yong ; Liu Yingyi
Author_Institution
Sch. of Autom. Sci. & Electr. Eng., Beihang Univ., Beijing, China
fYear
2013
fDate
21-23 Sept. 2013
Firstpage
28
Lastpage
32
Abstract
Experimental studies are reported that measuring results of electric field mill are inconsistency, which affects their measuring accuracy. This paper introduces the principle of electric field measurement. Statistical analysis of calibration experimental results shows that measurement data obey normal distribution rule. Correlation analysis result indicates that the distance between two electrodes of field mill has a strong linear correlation with measure results. Linear model is established with the method of regression analysis. Finally, residual test verify the rationality of regression model.
Keywords
calibration; correlation theory; data integrity; electric field measurement; regression analysis; calibration; correlation analysis; data consistency; electric field measurement; field mill electrodes; linear correlation; linear model; normal distribution rule; regression analysis; regression model; residual test; statistical analysis; Correlation; Electric fields; Electrodes; Fitting; Gaussian distribution; Transmission line measurements; Electric field mill; consistency; correlation; regression analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation, Measurement, Computer, Communication and Control (IMCCC), 2013 Third International Conference on
Conference_Location
Shenyang
Type
conf
DOI
10.1109/IMCCC.2013.14
Filename
6840403