Abstract :
Valve´s following-up movement has been a tough problem for the tradition valve possess piezoelectric pump. So studying the valve is needed. By this way it may support some useful information to make a further exploring of whether can regulate pump´s output by changing valve´s structure and material type. In order to find the effect that applied on the single conical shell valve pump. Valve´s Stress distribution has been analyzed. And valve´s kinematics model has also been set up. On these bases the relationship between the valve´s bending deformation and the valve´s parameter such as stiffness, quality etc has been got. Finally experiments has been implemented and proving the corresponding theoretical analysis. As the valve´s parameter has been chosen reasonable the pump´s working output is going to be 56 Hz in working frequency and the flow rate can reach 190 ml/min under the voltage sat as 220V.
Keywords :
bending; kinematics; piezoelectric devices; pumps; shells (structures); stress analysis; valves; bending deformation; frequency 56 Hz; quality; single conical shell valve piezoelectric pump; stiffness; valve kinematics model; valve stress distribution analysis; voltage 220 V; Computational fluid dynamics; Conical shell; Kinematics model; Piezoelectric; Pump; Valve;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Piezoelectricity, Acoustic Waves and Device Applications (SPAWDA), 2013 Symposium on
Conference_Location :
Changsha
Print_ISBN :
978-1-4799-3289-4
Type :
conf
DOI :
10.1109/SPAWDA.2013.6841076
Filename :
6841076
Link To Document :
بازگشت