DocumentCode
694461
Title
Simulation of field uniformity in a reverberation chamber
Author
Shuhong Wu ; Yalin Guan ; Jinhang Hu ; Lingling Wang ; Hongjuan Tang
Author_Institution
Inf. Eng. Sch., Commun. Univ. of China, Beijing, China
fYear
2013
fDate
12-13 Oct. 2013
Firstpage
707
Lastpage
710
Abstract
As a new and effective testing cite for electromagnetic compatibility test, the reverberation chamber, especially a newly built one, must verify its field uniformity. So, when undertaking a study on a reverberation chamber, its field uniformity is a key indicator. This article, in accordance with the actual dimension of a reverberation chamber, built an FEKO model, and calculated the electric field of the 8 vertices of the workspace, then verified the field uniformity of this reverberation chamber meet the IEC 61000-4-21 standard.
Keywords
IEC standards; electric fields; electromagnetic compatibility; method of moments; reverberation chambers; FEKO model; IEC 61000-4-21 standard; electric field; electromagnetic compatibility test; field uniformity; reverberation chamber; Cavity resonators; Electric fields; IEC standards; Mathematical model; Reverberation chambers; FEKO; Field Uniformity; Reverberation Chamber;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Science and Network Technology (ICCSNT), 2013 3rd International Conference on
Conference_Location
Dalian
Type
conf
DOI
10.1109/ICCSNT.2013.6967209
Filename
6967209