DocumentCode
700978
Title
Carbon dosage control for predenitrification processes
Author
Zhiguo Yuan ; Bogaert, Herwig ; Vanrolleghem, Peter ; Thoeye, Chris ; Vansteenkiste, Ghislain ; Verstraete, Willy
Author_Institution
Dept. of Appl. Math., Bio. & Proc. Contr., Univ. of Gent, Ghent, Belgium
fYear
1997
fDate
1-7 July 1997
Firstpage
3240
Lastpage
3245
Abstract
The external carbon dosage control for predenitrification processes is studied. The proposed strategy is to control the nitrate concentration in the anoxic zone at a low set-point. A model-based analysis of the denitrification process reveals that the optimal set-point for the nitrate concentration in the anoxic zone is about 1 mg.l-1. Three control laws are designed to control the anoxic zone nitrate concentration at its set-point for different measurement conditions. An effort is made in all the designs to make the control system as simple as possible. This includes the usage of simple control laws and few sensors, which reduces the implementation and maintenance cost of the control system. The analyses and designs are validated by simulation and experimental studies on a full scale plant.
Keywords
control system synthesis; control systems; maintenance engineering; optimal control; process control; three-term control; anoxic zone nitrate concentration; control law design; control system; different measurement conditions; external carbon dosage control; maintenance cost; model-based analysis; optimal set point; predenitrification processes; Analytical models; Biological system modeling; Carbon; Feedforward neural networks; Gain measurement; Mathematical model; Noise measurement; delay systems PID control; industry day; nonlinear dynamics;
fLanguage
English
Publisher
ieee
Conference_Titel
Control Conference (ECC), 1997 European
Conference_Location
Brussels
Print_ISBN
978-3-9524269-0-6
Type
conf
Filename
7082610
Link To Document