DocumentCode
702411
Title
Non-invasive torque estimation for broken bar detection in induction motors
Author
Eltabach, M. ; Charara, A. ; Zein, I.
Author_Institution
HEUDIASYC UMR 6599 - LATIM, Université de Technologie de Compiègne; BP 20529; 60205 Compiègne Cedex; France
fYear
2003
fDate
1-4 Sept. 2003
Firstpage
2794
Lastpage
2799
Abstract
Rotor asymmetries lead to perturbations of air-gap flux patterns in induction machines. These perturbations in flux components affect a number of components including currents and electromagnetic torque. The supervision of these signals enables early detection of such faults and assists in fault diagnosis. This paper studies the detection of rotor imperfections by spectral analysis of the electromagnetic torque, computed by two stator flux estimators using only noninvasive sensors such as current and voltage sensors. In a first approach, the Extended Luenberger Observer (ELO) is used to estimate stator flux components as well mechanical velocity. A second approach uses a nonlinear High Gain Observer (HGO) for the same purposes. Experimental results and comparison show the significant potential of these methods in detecting these types of faults.
Keywords
Electromagnetics; Observers; Rotors; Stators; Synchronous motors; Torque; Induction machines; Kalman filters; diagnostic; fault detection; observers;
fLanguage
English
Publisher
ieee
Conference_Titel
European Control Conference (ECC), 2003
Conference_Location
Cambridge, UK
Print_ISBN
978-3-9524173-7-9
Type
conf
Filename
7086465
Link To Document