DocumentCode :
703630
Title :
Weigthing hyperparameters for 3D Bayesian estimation in Eddy current tomography
Author :
Venard, Olivier ; Premei, Denis
Author_Institution :
L.E. Si.R., ENS Cachan, Cachan, France
fYear :
1998
fDate :
8-11 Sept. 1998
Firstpage :
1
Lastpage :
4
Abstract :
The skin effect is a major limitation for Eddy Current Tomography ECT. It limits its ability to image flaws inside electricaly conductive material. In this paper we tackle the inverse problem in a Bayesian framework which imply the computation of the hyperparameters defining the weight of the a priori in the estimate. To improve its performance regarding buried flaws, we suggest that hyperparameters of the inverse problem can´t be the same for each layer of discretization and we propose a method to bias them accordingly to the skin effect.
Keywords :
Bayes methods; computerised tomography; eddy currents; inverse problems; skin effect; 3D Bayesian estimation; Bayesian framework; ECT; buried flaws; eddy current tomography; electricaly conductive material; hyperparameters; inverse problem; skin effect; Bayes methods; Conductivity; Eddy currents; Image reconstruction; Inverse problems; Skin; Tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Signal Processing Conference (EUSIPCO 1998), 9th European
Conference_Location :
Rhodes
Print_ISBN :
978-960-7620-06-4
Type :
conf
Filename :
7090101
Link To Document :
بازگشت