DocumentCode :
704482
Title :
Finite element analysis of finger joint implant: A review
Author :
Aziz, Tariq ; Al-Ahmari, Abdur Rehman M. ; Al Khawashki, Hazem ; Darwish, S.M. ; Al Badr, Fahad Badr M.
Author_Institution :
Adv. Manuf. Inst., King Saud Univ., Riyadh, Saudi Arabia
fYear :
2015
fDate :
3-5 March 2015
Firstpage :
1
Lastpage :
8
Abstract :
In orthopedic surgery, a semi constraint hinged prosthesis is inserted between the metacarpal and the first phalanx of the index finger. The purpose of the Implants development to allow maximum joint flexibility, and reduce joint pain effectively. In this paper; first the review of all the related areas is carried and after that with help of an implant study on loading conditions, deformation and stresses is analyzed. The research contribution is the development of a new implant with brief literature review and aligning the implant development criteria with different prospective of literature. The data from Computer Tomography is imported into MIMICS software and then segmentation is performed. The 3-D model for the finger joints is developed using Solid works software. Fixation of the implant to the gap location was performed using MIMICS. The analysis of normal finger with respect to the implanted is done through ANSYS software. The materials were assumed to be homogeneous, isotropic and linear elastic. Additive manufacturing technology is used to finally manufacture the implant.
Keywords :
biomechanics; bone; computer aided analysis; computer software; computerised tomography; deformation; elasticity; finite element analysis; image segmentation; medical image processing; orthopaedics; prosthetics; rapid prototyping (industrial); surgery; yield stress; 3D finger joint model; ANSYS software; MIMICS software-imported CT data; MIMICS software-imported compute tomography data; MIMICS software-performed joint implant fixation; Materilaise´s Interactive Medical Image Control System; additive manufacturing technology; analysis system software; effective joint pain reduction; finger joint implant fixation; finger joint implant manufacture; finite element analysis; gap location-fixed finger joint implant; homogeneous joint implant materials; image segmentation; implant development criteria; implant loading conditions; index finger phalanx; isotropic joint implant materials; joint implant deformation analysis; joint implant development; joint implant stress analysis; linear elastic joint implant materials; maximum joint flexibility; metacarpal-phalanx interface; normal finger analysis; orthopedic surgery; reduced joint pain; semi constraint-hinged prosthesis; solid works software-developed finger joint model; three-dimensional finger joint model; Finite element analysis; Implants; Joints; Solid modeling; Surgery; Thumb; ANSYS software; Additive manufacturing; CATIA; Fingers joint; Finite element Analysis; MIMICS;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Engineering and Operations Management (IEOM), 2015 International Conference on
Conference_Location :
Dubai
Print_ISBN :
978-1-4799-6064-4
Type :
conf
DOI :
10.1109/IEOM.2015.7093857
Filename :
7093857
Link To Document :
بازگشت