DocumentCode :
709042
Title :
Investigation of S21 magnitude extraction methodologies by using a pattern generator and sampling oscilloscope
Author :
Xinyun Guo ; Shringarpure, Ketan ; Daou, Fadi ; Jun Fan
Author_Institution :
EMC Lab., Missouri Univ. of Sci. & Technol., Rolla, MO, USA
fYear :
2015
fDate :
15-21 March 2015
Firstpage :
181
Lastpage :
186
Abstract :
S-parameter measurements of a digital link path are measured with VNAs or high-end TDRs. For multi-port in-situ measurements, these become inconvenient and time consuming. However, it can be handled more conveniently in the time domain (TD) by using a pattern generator and a multichannel sampling oscilloscope, which are used for eye-diagram measurements. This paper outlines and compares three methods to extract S21 magnitude from the time domain measurements using a pattern generator and a sampling oscilloscope for any channel. The setup differs in terms of the input waveform and the processing. The comparison provides insight into the advantages and limitations of each method.
Keywords :
S-parameters; oscilloscopes; signal generators; S-parameter measurements; S21 magnitude extraction methodologies; digital link path; eye-diagram measurements; multichannel sampling oscilloscope; pattern generator; time domain measurements; Clocks; Frequency-domain analysis; Generators; Harmonic analysis; Noise; Oscilloscopes; Transmission line measurements; Oscilloscope; Pattern generator; S21; TDT;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility and Signal Integrity, 2015 IEEE Symposium on
Conference_Location :
Santa Clara, CA
Print_ISBN :
978-1-4799-1992-5
Type :
conf
DOI :
10.1109/EMCSI.2015.7107682
Filename :
7107682
Link To Document :