Abstract
This electronic document is about comparison of the methods and systems for the measurement of the ionosphere used at the geophysical observatory Pruhonice (50N, 14.5E). Three systems for ionospheric monitoring are installed at the station. The first system for the monitoring of the ionosphere is Digisonde, the second system is dual frequency GNSS receiver and the third system is continuous Doppler sounding. Each system has its benefits and weaknesses which are compared in this paper.
Keywords
ionosphere; ionospheric measuring apparatus; satellite navigation; continuous Doppler sounding; device comparison; digisonde; dual frequency GNSS receiver; electronic document; geophysical observatory Pruhonice; ionosphere measurement; ionosphere monitoring; Frequency measurement; Global Positioning System; Ionosphere; Observatories; Plasma measurements; Plasmas; Receivers; Digisonde; GNSS receiver; Total Electron Content (TEC); continuous Doppler sounding; ionosphere;