DocumentCode :
713994
Title :
Effect of test site arrangement for large systems on test validity according to EN 61000-4-3
Author :
Hallon, Jozef ; Bittera, Mikulas ; Kovac, Karol
Author_Institution :
Inst. of Electr. Eng. of Fac. of Electr. Eng. & Inf. Technol., Slovak Univ. of Technol., Bratislava, Slovakia
fYear :
2015
fDate :
21-22 April 2015
Firstpage :
61
Lastpage :
64
Abstract :
This paper deals with analysis of effect of a test site geometrical arrangement on the test validity when immunity test of large systems against radiated radiofrequency electromagnetic field is performed. Such a system often equipped with complex cabling cannot be arranged in accordance with normalized setup described by a standard. This leads to lower test validity. The analysis is focused on effect of cabling arrangement on induced current flowing through the cabling. Results obtained by numerical simulations are compared with measurements.
Keywords :
electromagnetic fields; immunity testing; EN 61000-4-3; cabling arrangement; immunity test; induced current flowing; large systems; numerical simulations; radiated radiofrequency electromagnetic field; test site geometrical arrangement; test validity; Immunity testing; Impedance; Load modeling; Power cables; Power supplies; Standards; Electromagnetic compatibility (EMC); immunity testing; influence of electromagnetic field; numerical EM simulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radioelektronika (RADIOELEKTRONIKA), 2015 25th International Conference
Conference_Location :
Pardubice
Print_ISBN :
978-1-4799-8117-5
Type :
conf
DOI :
10.1109/RADIOELEK.2015.7129038
Filename :
7129038
Link To Document :
بازگشت