DocumentCode
715558
Title
Target temperature effect on eddy-current displacement sensing
Author
Vyroubal, Darko ; Lackovic, Igor
Author_Institution
Karlovac Univ. of Appl. Sci., Karlovac, Croatia
fYear
2015
fDate
13-15 April 2015
Firstpage
1
Lastpage
5
Abstract
Target temperature effect on eddy current displacement sensing is analyzed and evaluated by simulation. The equivalent target quality factor is detected as the main factor that, along with the probe equivalent quality factor, determines this effect. It manifests in ambiguity of displacement measurement, as well as, masking the displacement variation by target temperature variation, and vice versa. The analysis and the simulation show that there is an optimal operating frequency for minimum sensitivity over an acceptable displacement range.
Keywords
displacement measurement; eddy currents; electric current measurement; electric sensing devices; temperature measurement; temperature sensors; displacement measurement; eddy-current displacement sensing; equivalent target quality factor; target temperature effect; Eddy currents; Probes; Q-factor; Sensitivity; Temperature; Temperature measurement; Temperature sensors; displacement; eddy-currents; sensing; target; temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Sensors Applications Symposium (SAS), 2015 IEEE
Conference_Location
Zadar
Type
conf
DOI
10.1109/SAS.2015.7133621
Filename
7133621
Link To Document