DocumentCode :
715975
Title :
Uncertainty evaluation of 2013 TL METODE link calibration tour
Author :
Shinn-Yan Lin ; Yi-Jiun Huang ; Wen-Hung Tseng
Author_Institution :
Telecommun. Labs., Chunghwa Telecom Co., Ltd., Taoyuan, Taiwan
fYear :
2015
fDate :
12-16 April 2015
Firstpage :
226
Lastpage :
229
Abstract :
We targeting analyzed the UTC link delay of GPS station PTBB of PTB to TWTF of TL and expressed it as 3 groups: the uncompensated GPS common clock difference measurements, cable delay measurement, and the total delay variations of fixed GPS stations and travelling calibrator used in this METODE calibration tour. The total delay variation of fixed GPS stations PTBB and TWTF was evaluated by monitoring their long-term CCD of the same type receiver more than 350 days. For the BIPM travelling calibrator BP1C and BP0U, we used a moving cesium clock method to evaluate their instability of total delay in different antenna position. Our study was helpful for clarifying the uncertainty composition of the current PTB-TL link and could reduce it.
Keywords :
Global Positioning System; atomic clocks; calibration; delays; measurement standards; measurement uncertainty; 2013 TL METODE link calibration tour; GPS station PTBB; UTC link delay; cable delay measurement; cesium clock method; fixed GPS stations; total delay variations; travelling calibrator; uncertainty evaluation; uncompensated GPS common clock difference measurements; Calibration; Charge coupled devices; Delays; Global Positioning System; Receivers; Uncertainty; METODE Calibration; uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency Control Symposium & the European Frequency and Time Forum (FCS), 2015 Joint Conference of the IEEE International
Conference_Location :
Denver, CO
Print_ISBN :
978-1-4799-8865-5
Type :
conf
DOI :
10.1109/FCS.2015.7138829
Filename :
7138829
Link To Document :
بازگشت