DocumentCode
719698
Title
Design and development of an eletro-optic type flow transmitter using Mach-Zehnder Interferometer
Author
Kumar, Brajesh ; Sinha, Sunita ; Mandal, N.
Author_Institution
Dept. of Electron. Eng., Indian Sch. of Mines, Dhanbad, India
fYear
2015
fDate
28-30 May 2015
Firstpage
602
Lastpage
606
Abstract
The Rotameter is a variable area, local indicator type flow sensor. Hence to transmit reading of Rotameter at a remote distance, some special technique is needed. The transmission of electrical signal is dangerous for inflammable industry. In this paper, an electro-optic type flow transmitter has been proposed. The float movement of Rotameter is converted into an electrical signal with the help of inductive pickup coil and Maxwell Bridge. This electrical signal is applied in electro-optic Mach-zehnder Interferometer, which gives the optical signal for transmitting to remote location. The necessary theoretical equations, along with the experimental results are reported in this paper.
Keywords
Mach-Zehnder interferometers; coils; electro-optical devices; flow sensors; inductance measurement; inductive sensors; optical sensors; optical transmitters; pick-ups; Maxwell bridge; electrical signal transmission; electrooptic Mach-Zehnder Interferometer; eletrooptic type flow transmitter; flow sensor; inductive pickup coil; inflammable industry; rotameter; Capacitance; Electrooptical waveguides; Q measurement; Transducers; Flow transmitter; Mach-Zehnder Interferometer; Rotameter; electro-optic; inductive pickup; transducer;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Instrumentation and Control (ICIC), 2015 International Conference on
Conference_Location
Pune
Type
conf
DOI
10.1109/IIC.2015.7150813
Filename
7150813
Link To Document