DocumentCode
720147
Title
Real-time velocity profile measurement in two-phase oil/gas flow by twin-plane segmented ECT system
Author
Elmy, J.M. ; Hanis, L.M.A. ; Ruzairi, A.R. ; Omar, M.F.M.
Author_Institution
Dept. of Mechatron. & Robot. Eng., Univ. Tun Hussein Onn Malaysia, Batu Pahat, Malaysia
fYear
2015
fDate
11-14 May 2015
Firstpage
1567
Lastpage
1572
Abstract
In today´s industrial environment, it is common to see the use of pipes or vessels to transfer mixtures of materials or products along them. However, the measurement of the amount delivered can only be done in one way: isolate the components first; then meter, weigh or measure the volume for each individual component. This measuring procedure often stalls the production rate. This work implements a noninvasive, real time monitoring system to measure the flow concentration and velocity distributions of a two-phase (liquid-gas) flow. The system uses the combination of a specially designed twin-plane segmented Electrical Capacitance Tomography (ECT) sensor with 16 portable electrodes and the cross-correlation method as the velocity measurement technique. The measured values or data from the ECT sensor will be manipulated to reconstruct the cross sectional image of the pipeline by computer programming. These images are then cross-correlated to obtain the velocity profile of the multiphase flow. The visualization results deliver information regarding the flow regime, superficial velocity and concentration distribution in two-phase flow rate measurement system. The information obtained is able to improve: the process equipment´s design, verification of existing computational modeling and simulation techniques. This technique has the possibility to promote an excellent opportunity to build methods for measuring the velocity field in multiphase flow by using noninvasive technique and cross-correlating.
Keywords
capacitance measurement; flow visualisation; portable instruments; real-time systems; two-phase flow; velocity measurement; cross-correlation method; flow concentration; image reconstruction; portable electrodes; real time monitoring system; real-time velocity profile measurement; twin-plane segmented ECT system; twin-plane segmented electrical capacitance tomography sensor; two-phase flow rate measurement system; two-phase oil-gas flow; velocity distributions; velocity measurement; Correlation; Electrodes; Fluid flow; Fluid flow measurement; Liquids; Sensors; Velocity measurement; Segmented ECT; cross-correlation; oil/gas; two-phase; velocity profile;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International
Conference_Location
Pisa
Type
conf
DOI
10.1109/I2MTC.2015.7151512
Filename
7151512
Link To Document