Title :
Automated robust metric calibration of multi-focus plenoptic cameras
Author :
Heinze, Christian ; Spyropoulos, Stefano ; Hussmann, Stephan ; Perwass, Christian
Author_Institution :
Raytrix GmbH, Kiel, Germany
Abstract :
The concept of plenoptic cameras has existed since the early 1900s, with recent advances in computational power making them a viable tool for industrial applications. Plenoptic cameras can give 3D information about the scene with one camera, one lens, and a single image. This is possible by placing a microlens array directly in front of the image sensor. The depth estimation is based on disparities observed in individual microlens images, similar to stereo camera approaches. To relate these so-called virtual depth units to metric distances, a camera calibration must be performed. This paper presents a robust, automated camera calibration technique, which introduces new ways to model a multi-focus plenoptic camera.
Keywords :
calibration; cameras; image sensors; microlenses; microsensors; sensor arrays; spatial variables measurement; stereo image processing; automated camera calibration technique; automated robust metric calibration; depth estimation; image sensor; microlens imaging array; multifocus plenoptic camera; stereo camera approach; Calibration; Cameras; Estimation; Extraterrestrial measurements; Lenses; Three-dimensional displays; MLA; Plenoptic camera; Raytrix; focused plenoptic; metric calibration; plenoptic 2.0;
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International
Conference_Location :
Pisa
DOI :
10.1109/I2MTC.2015.7151596