DocumentCode :
72085
Title :
A Low Component Count Series Voltage Compensation Scheme for DFIG WTs to Enhance Fault Ride-Through Capability
Author :
Ambati, Bharath Babu ; Kanjiya, Parag ; Khadkikar, Vinod
Author_Institution :
Inst. Center for Energy, Masdar Inst. of Sci. & Technol., Abu Dhabi, United Arab Emirates
Volume :
30
Issue :
1
fYear :
2015
fDate :
Mar-15
Firstpage :
208
Lastpage :
217
Abstract :
Fault ride-through (FRT) operation has been a challenge for the doubly fed induction generator (DFIG) based wind turbines (WTs) as the stator winding is directly connected to the grid. Additionally, several grid codes have been established for the grid interconnection of WTs, which demand the WT to stay connected and provide the predefined reactive current support to the grid during FRT operation. The series voltage compensation (SeVC) based FRT schemes for DFIG WTs outperforms all others in terms of smooth transient performance. However, such FRT schemes require an additional voltage-source converter (VSC) and a bulkier series transformer to provide the SeVC. This paper proposes a low component count SeVC scheme that is applicable to both individual WTs and wind parks to cope up with the recent grid codes requirements. The proposed configuration eliminates the need of a series transformer and an additional VSC for the SeVC operation with the use of three additional IGBTs/switches. Furthermore, a coordinated control strategy is proposed to control the WT that enhance its FRT capabilities. The proposed low component count FRT scheme and coordinated control strategy are validated using the detailed mathematical modeling and simulation of 1.5 MW DFIG WT.
Keywords :
asynchronous generators; insulated gate bipolar transistors; power convertors; power generation control; power generation faults; power grids; power system interconnection; power transformers; power transistors; stators; voltage control; wind power plants; wind turbines; DFIG WT; FRT capabilities; FRT operation; FRT schemes; IGBT; SeVC operation; VSC; control strategy; count series voltage compensation scheme; doubly fed induction generator; fault ride-through capability; grid codes; grid interconnection; power 1.5 MW; reactive current support; series transformer; stator winding; voltage-source converter; wind parks; wind turbines; Power conversion; Rotors; Stator windings; Voltage control; Windings; Doubly fed induction generator (DFIG); fault ride through (FRT); grid faults; nine-switch converter; series voltage compensation (SeVC); unbalance; wind turbine (WT);
fLanguage :
English
Journal_Title :