DocumentCode
72318
Title
Measurement and Calculation of Unbalanced Magnetic Pull in Wound Rotor Induction Machine
Author
Dorrell, David G. ; Kayani, Obaid
Author_Institution
Sch. of Electr., Mech. & Mechatron. Syst., Univ. of Technol. Sydney, Ultimo, NSW, Australia
Volume
50
Issue
11
fYear
2014
fDate
Nov. 2014
Firstpage
1
Lastpage
4
Abstract
This paper addresses the measurement and calculation of unbalanced magnetic pull (UMP) in a wound rotor induction machine. A new rig for measuring UMP is presented. To our knowledge, this type of rig has not been tested before. This paper details the force calculation method and a method for splitting the UMP and torque. Wound rotor induction machines are now popular as generators in wind turbines. It is important to maintain good operation and low bearing wear, and the UMP in these machines is higher than that of the cage-rotor equivalent because the cage damps the UMP. There is little literature on the UMP in a wound rotor machine.
Keywords
asynchronous machines; rotors; UMP; cage-rotor equivalent; force calculation method; unbalanced magnetic pull; wear; wind turbines; wound rotor induction machine; Current measurement; Force; Integrated circuit modeling; Magnetic levitation; Rotors; Stators; Torque; Force; induction motors; unbalanced magnetic pull (UMP);
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2014.2326414
Filename
6971699
Link To Document