• DocumentCode
    72318
  • Title

    Measurement and Calculation of Unbalanced Magnetic Pull in Wound Rotor Induction Machine

  • Author

    Dorrell, David G. ; Kayani, Obaid

  • Author_Institution
    Sch. of Electr., Mech. & Mechatron. Syst., Univ. of Technol. Sydney, Ultimo, NSW, Australia
  • Volume
    50
  • Issue
    11
  • fYear
    2014
  • fDate
    Nov. 2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper addresses the measurement and calculation of unbalanced magnetic pull (UMP) in a wound rotor induction machine. A new rig for measuring UMP is presented. To our knowledge, this type of rig has not been tested before. This paper details the force calculation method and a method for splitting the UMP and torque. Wound rotor induction machines are now popular as generators in wind turbines. It is important to maintain good operation and low bearing wear, and the UMP in these machines is higher than that of the cage-rotor equivalent because the cage damps the UMP. There is little literature on the UMP in a wound rotor machine.
  • Keywords
    asynchronous machines; rotors; UMP; cage-rotor equivalent; force calculation method; unbalanced magnetic pull; wear; wind turbines; wound rotor induction machine; Current measurement; Force; Integrated circuit modeling; Magnetic levitation; Rotors; Stators; Torque; Force; induction motors; unbalanced magnetic pull (UMP);
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2014.2326414
  • Filename
    6971699