DocumentCode :
72367
Title :
Fault-Tolerant Control of Wind Turbines: A Benchmark Model
Author :
Odgaard, Peter F. ; Stoustrup, Jakob ; Kinnaert, Michel
Author_Institution :
Aalborg Univ., Aalborg, Denmark
Volume :
21
Issue :
4
fYear :
2013
fDate :
Jul-13
Firstpage :
1168
Lastpage :
1182
Abstract :
This paper presents a test benchmark model for the evaluation of fault detection and accommodation schemes. This benchmark model deals with the wind turbine on a system level, and it includes sensor, actuator, and system faults, namely faults in the pitch system, the drive train, the generator, and the converter system. Since it is a system-level model, converter and pitch system models are simplified because these are controlled by internal controllers working at higher frequencies than the system model. The model represents a three-bladed pitch-controlled variable-speed wind turbine with a nominal power of 4.8 MW. The fault detection and isolation (FDI) problem was addressed by several teams, and five of the solutions are compared in the second part of this paper. This comparison relies on additional test data in which the faults occur in different operating conditions than in the test data used for the FDI design.
Keywords :
actuators; blades; fault diagnosis; fault tolerance; sensors; variable speed drives; wind turbines; FDI design; FDI problem; accommodation schemes; actuator; converter system; drive train; fault detection and isolation problem; fault-tolerant control; generator; internal controllers; nominal power; pitch system; sensor; system faults; system model; system-level model; test benchmark model; three-bladed pitch-controlled variable-speed wind turbine; wind turbines; Benchmark modeling; fault detection; fault isolation; fault-tolerant control (FTC); wind turbines;
fLanguage :
English
Journal_Title :
Control Systems Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
1063-6536
Type :
jour
DOI :
10.1109/TCST.2013.2259235
Filename :
6518165
Link To Document :
بازگشت