    A study of the suitability of new type carbon fiber electric heating soft board applying to intermitten heating room

  • Author

    Zheng Yu ; Piao Zai-lin ; Fang Jing-jing ; Chen Zhong-wei

  • Author_Institution
    Coll. of Inf. & Electr. Eng., Shenyang Agric. Univ., Shenyang, China
  • fYear
    2015
  • fDate
    23-25 May 2015
  • Firstpage
    6269
  • Lastpage
    6271
  • Abstract
    Experimental methods were taken to analyze the suitability of electric-powered radiant floor heating applying to intermittent heating room. The thermal comfort, response time and energy consumption of domestic air conditioning and electric heating carpet was compared. The electric heating carpet was dominant on response time of heating the room´s lower space. The operative temperature of lower part of the room was higher than the upper part when carbon fiber electric heating soft board heating stabilized, while the air conditioning leads to an opposite result. The results prove that the temperature gradient was smaller when carbon fiber electric heating soft board was utilized, which makes up its lower COP to some extent.
  • Keywords
    air conditioning; carbon fibres; electric heating; power consumption; carbon fiber electric heating; domestic air conditioning; electric heating carpet; electric-powered radiant floor heating; energy consumption; intermittent heating room; response time; soft board; thermal comfort; Carbon; Heating; Carbon Fiber Electric Heating Soft board; heating effectiveness;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control and Decision Conference (CCDC), 2015 27th Chinese
  • Conference_Location
    Qingdao
  • Print_ISBN
    978-1-4799-7016-2
  • Type

    conf

  • DOI
    10.1109/CCDC.2015.7161941
  • Filename
    7161941