• DocumentCode
    725066
  • Title

    Free-breathing perfusion MRI using multislice pCASL

  • Author

    Hao Song ; Wenyang Liu ; Dan Ruan ; Pohmann, Rolf ; Stenger, V. Andrew ; Fernandez-Seara, Maria A. ; Sungkyu Jung ; Gach, H. Michael

  • Author_Institution
    Dept. of Radiol., Univ. of Pittsburgh, Pittsburgh, PA, USA
  • fYear
    2015
  • fDate
    16-19 April 2015
  • Firstpage
    1474
  • Lastpage
    1477
  • Abstract
    Arterial spin labeling (ASL) is a difference imaging method that is sensitive to motion between successive label and control acquisitions, restricting its use in the abdomen. Respiratory motion prediction (RMP) using an artificial neutral network (ANN) and navigator echoes was developed to enable free-breathing perfusion measurements of the kidney using pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging (MRI).
  • Keywords
    biomedical MRI; blood vessels; image motion analysis; kidney; medical image processing; pneumodynamics; ANN; abdomen; arterial spin labeling; artificial neutral network; control acquisitions; free-breathing perfusion MRI; kidney; magnetic resonance imaging; motion sensitivity; multislice PCASL; navigator echoes; pseudocontinuous arterial spin labeling; respiratory motion prediction; Artificial neural networks; Blood; Imaging; Kidney; Labeling; Navigation; Prediction algorithms; MRI; artificial neutral network; kidney perfusion; pCASL; respiratory motion prediction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging (ISBI), 2015 IEEE 12th International Symposium on
  • Conference_Location
    New York, NY
  • Type

    conf

  • DOI
    10.1109/ISBI.2015.7164155
  • Filename
    7164155