DocumentCode :
726719
Title :
Detection of eccentricity fault using slot leakage flux monitoring
Author :
Hanfeng Wang ; Xiaohua Bao ; Chong Di ; Zhiheng Cheng
Author_Institution :
Sch. of Electr. Eng. & Autom., Hefei Univ. of Technol., Hefei, China
fYear :
2015
fDate :
1-5 June 2015
Firstpage :
2188
Lastpage :
2193
Abstract :
Eccentricity is a common fault in the running of electrical machines. Aimed at the problem, a new approach to detect eccentricity fault is presented by monitoring the slot leakage flux of stator in this paper. In order to measure the slot leakage flux, two placements of search coil in the stator slot are applied. Firstly, the theoretical analysis shows the slot leakage flux contains more information about eccentricity fault than the stator current does. Then the submersible motor as a model, the induced voltages of search coil and the stator currents are obtained by finite element simulation under healthy motor, static, dynamic and mixed eccentricity, respectively. And various analysis and comparisons of simulations are made. The results show that monitoring the slot leakage flux is effective and has more advantages than the motor current signature analysis.
Keywords :
coils; electric motors; fault diagnosis; finite element analysis; magnetic flux; magnetic leakage; eccentricity fault; electrical machines; finite element simulation; motor current signature analysis; search coil; slot leakage flux monitoring; stator current; stator slot; submersible motor; Harmonic analysis; Induction motors; Magnetic fields; Monitoring; Rotors; Stator windings; Eccentricity; search coil; slot leakage flux; submersible motor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
Conference_Location :
Seoul
Type :
conf
DOI :
10.1109/ICPE.2015.7168080
Filename :
7168080
Link To Document :
بازگشت