DocumentCode :
726773
Title :
Diagnosis technique for stator winding inter-turn fault in BLDC motor using detection coil
Author :
Seung-Tae Lee ; Kyung-Tae Kim ; Jin Hur
Author_Institution :
Sch. of Electr. Eng., Univ. of Ulsan, Ulsan, South Korea
fYear :
2015
fDate :
1-5 June 2015
Firstpage :
2925
Lastpage :
2931
Abstract :
Brushless direct-current (BLDC) motors are widely used in industrial applications. These motors should be considered for high stability and reliability under faults which can seriously threaten safe operation. Among these fault types, a stator winding inter-turn fault (ITF) is one of the most common faults that occur in BLDC motors. Moreover, the propagation of the fault could quickly lead to shutdown of the motor within a few seconds. In order to prevent the problem, we proposed a diagnosis technique of ITF using variations of back electromotive force generated in detection coils in BLDC motors. The technique can relatively achieve more rapid response and lower cost than previous detection techniques, because the proposed technique does not require spectral analysis and complicated computation. The detection technique is verified by simulation and experiment under dynamic fault.
Keywords :
brushless DC motors; coils; electric potential; fault diagnosis; stators; BLDC motor; ITF; back electromotive force; brushless direct-current motor; detection coil; industrial application; motor shutdown; spectral analysis; stator winding interturn fault diagnosis technique; Brushless DC motors; Circuit faults; Finite element analysis; Induction motors; Magnetic fields; Brushless DC motor; fault detection; fault diagnosis; inter-turn fault;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
Conference_Location :
Seoul
Type :
conf
DOI :
10.1109/ICPE.2015.7168191