DocumentCode :
727535
Title :
Single-transmitter setup on nonlinear mixing to measure acoustic nonlinearity of first order
Author :
Melchor, J. ; Peralta, L. ; Rus, G. ; Saffari, N. ; Soto, J.
Author_Institution :
Dept. Struct. Mech., Univ. of Granada, Granada, Spain
fYear :
2015
fDate :
10-12 June 2015
Firstpage :
1
Lastpage :
4
Abstract :
In this study, the acoustic nonlinearity of water was investigated using a variation of the collinear wave mixing method. One single transducer, driven at two different frequencies fa and fb, was used to generate a third frequency component at fa - fb, fa + fb, 2fa and 2fb. Such a configuration allows to cancel out system nonlinearities since no amplification of the signal beyond 10V is needed. Perturbation solutions of nonlinear parameter in water are analytically calculated and validated with experimental measurements.
Keywords :
mixing; nonlinear acoustics; water; H2O; collinear wave mixing method; first order acoustic nonlinearity measurement; nonlinear mixing; perturbation solutions; single-transducer setup; single-transmitter setup; water; Area measurement; Kinematics; Lead; Transducers; Voltage control; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonic Characterization of Bone (ESUCB), 2015 6th European Symposium on
Conference_Location :
Corfu
Type :
conf
DOI :
10.1109/ESUCB.2015.7169919
Filename :
7169919
Link To Document :
بازگشت