DocumentCode
729029
Title
Calibration and uncertainty evaluation of a 3-axis probe for EMC testing
Author
Sittakul, V. ; Pasakawee, S. ; Karanun, K.
Author_Institution
Electr. Metrol. Dept., Nat. Inst. of Metrol. (Thailand), Pathumthani, Thailand
fYear
2015
fDate
26-29 May 2015
Firstpage
388
Lastpage
390
Abstract
This paper proposes a calibration method for a 3-axis probe for electromagnetic compatibility (EMC) testing including its uncertainty evaluation. Initially, the proposed calibration system for a 3-axis probe is demonstrated. Then, electromagnetic field theory is applied to the system in order to determine the incident electric field at the probe. Finally, the uncertainty evaluation, an important measurement quantity for calibration, is calculated.
Keywords
calibration; electromagnetic compatibility; electromagnetic field theory; probes; 3-axis probe; EMC testing; calibration method; electromagnetic compatibility testing; electromagnetic field theory; uncertainty evaluation; Calibration; Electromagnetic compatibility; Horn antennas; Measurement uncertainty; Probes; Standards; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (APEMC), 2015 Asia-Pacific Symposium on
Conference_Location
Taipei
Print_ISBN
978-1-4799-6668-4
Type
conf
DOI
10.1109/APEMC.2015.7175226
Filename
7175226
Link To Document