• DocumentCode
    729037
  • Title

    Quantification of minimal needed cable terminations

  • Author

    van Leersum, B.J.A.M. ; Buesink, F.J.K. ; Leferink, F.B.J.

  • Author_Institution
    Univ. of Twente, Enschede, Netherlands
  • fYear
    2015
  • fDate
    26-29 May 2015
  • Firstpage
    470
  • Lastpage
    473
  • Abstract
    Cable terminations act as a boundary for common mode currents for all screened cable entries. Those common mode currents are attenuated by breaking up and shorting the common mode current paths, for instance between the inside and outside of the equipment cabinet. In this paper, cable terminations have been modelled as magnetically coupled loops with a bonding resistance and this model has been validated. The minimal needed bonding resistance has been established based on measurements and calculations.
  • Keywords
    electric connectors; bonding resistance; common mode current; magnetically coupled loop; minimal needed cable termination quantification; Bonding; Cable shielding; Couplings; Current measurement; Electromagnetic compatibility; Frequency measurement; Resistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (APEMC), 2015 Asia-Pacific Symposium on
  • Conference_Location
    Taipei
  • Print_ISBN
    978-1-4799-6668-4
  • Type

    conf

  • DOI
    10.1109/APEMC.2015.7175236
  • Filename
    7175236