DocumentCode :
729066
Title :
Comparison between latency insertion method (LIM) and relaxation method in thermal integrity analysis
Author :
Sakamoto, Kazuki ; Sekine, Tadatoshi ; Asai, Hideki
Author_Institution :
Dept. of Mech. Eng., Shizuoka Univ., Hamamatsu, Japan
fYear :
2015
fDate :
26-29 May 2015
Firstpage :
341
Lastpage :
344
Abstract :
This paper describes comparisons between the latency insertion method (LIM) and the successive over-relaxation (SOR) method in a thermal integrity analysis. A recent research indicates that LIM is adequate for the thermal simulation based on a resistive equivalent circuit model, which basically requires a DC analysis, though the method is one of the transient analysis methods. On the other hand, as is well known, the resistive network can be solved efficiently by using an iterative method such as the SOR method. We discuss the efficiencies of the methods by comparing the numerical results of example thermal simulations for a microchannel structure in a three-dimensional integrated circuit.
Keywords :
equivalent circuits; iterative methods; relaxation; thermal analysis; thermal management (packaging); three-dimensional integrated circuits; transient analysis; 3D integrated circuit; LIM; SOR method; iterative method; latency insertion method; resistive equivalent circuit model; successive over-relaxation method; thermal integrity analysis; thermal simulation; transient analysis methods; Coolants; Heating; Microchannels; Periodic structures;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (APEMC), 2015 Asia-Pacific Symposium on
Conference_Location :
Taipei
Print_ISBN :
978-1-4799-6668-4
Type :
conf
DOI :
10.1109/APEMC.2015.7175274
Filename :
7175274
Link To Document :
بازگشت