DocumentCode :
729116
Title :
Effects of imbalance on conducted immunity of a PLC link onto a DC power-bus for spacecraft
Author :
Grassi, F. ; Spadacini, G. ; Pignari, S.A.
Author_Institution :
Dept. of Electron., Inf. & Bioeng, Politec. di Milano, Milan, Italy
fYear :
2015
fDate :
26-29 May 2015
Firstpage :
665
Lastpage :
668
Abstract :
In this work, conducted-noise propagation in a Power Line Communications (PLC) link implemented on a spacecraft dc power-bus and involving differential signaling is investigated by resorting to modal analysis. The study mainly focuses on the detrimental effects on conducted immunity owing to the imbalance possibly introduced by the power units and the PLC modems. To this end, a suitable circuit interpretation of the propagation paths associated with common-mode (CM) and differential-mode (DM) components of the noise generated by the dc-dc converters is proposed, and the significant role that CM rejection properties of the modems play on immunity performance of the PLC link is outlined.
Keywords :
carrier transmission on power lines; modal analysis; space vehicles; DC-DC converters; PLC link; common-mode components; differential-mode components; modal analysis; power line communications link; spacecraft DC power-bus; DC-DC power converters; Integrated circuit modeling; Modems; Noise; Power line communications; Space vehicles; Transfer functions;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (APEMC), 2015 Asia-Pacific Symposium on
Conference_Location :
Taipei
Print_ISBN :
978-1-4799-6668-4
Type :
conf
DOI :
10.1109/APEMC.2015.7175334
Filename :
7175334
Link To Document :
بازگشت