DocumentCode
729659
Title
Validation of the methodology of lumen depreciation acceleration of LED lighting
Author
Guangjun Lu ; Yuan, Cadmus ; Bo Sun ; Bo Li ; Xuejun Fan ; Zhang, G.Q.
Author_Institution
Beijing Res. Center, Delft Univ. of Technol., Beijing, China
fYear
2013
fDate
10-12 Nov. 2013
Firstpage
154
Lastpage
157
Abstract
The 2-stage acceleration theory based accelerated lumen depreciation test method for LED lamps/luminaires was released recently as a standard-CSA020, which can reduce the lifetime test from 6,000 hours to less than 2,000 hours. However, to perform as a methodology in the application of that method, still some concerns existed. This paper validated that methodology by experimentally investigation on those major concerns. Results show recent lumen measurement system can meet the measurement error requirement and the criterion setting for over temperature protection function triggering in CSA020 can work. Probably the improvement of chamber´s design to meet the requirement of temperature acceleration in CSA020 is in need.
Keywords
LED lamps; lighting; measurement errors; 2-stage acceleration theory; LED lamps; LED lighting; LED luminaires; accelerated lumen depreciation test method; criterion setting; lumen depreciation acceleration; lumen measurement system; measurement error requirement; temperature protection function; Acceleration; Lifetime estimation; Lighting; Measurement errors; Measurement uncertainty; Temperature distribution; Temperature measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid State Lighting (ChinaSSL), 2013 10th China International Forum on
Conference_Location
Beijing
Print_ISBN
978-1-4799-2249-9
Type
conf
DOI
10.1109/SSLCHINA.2013.7177337
Filename
7177337
Link To Document