DocumentCode :
731885
Title :
A 2-axis gyroscope with a synchronously-driven dual mass
Author :
Akashi, T. ; Funabashi, H. ; Omura, Y. ; Fujiyoshi, M. ; Hata, Y. ; Nonomura, Y.
Author_Institution :
Toyota Central R&D Labs., Inc., Nagakute, Japan
fYear :
2015
fDate :
21-25 June 2015
Firstpage :
1243
Lastpage :
1246
Abstract :
We report a detuned 2-axis yaw-and-roll gyroscope with a single sensor element. We designed and fabricated a novel structure composed of a synchronously driven dual mass and three types of supporting beams to limit the movable direction of each mass. The designed resonant frequencies agreed well with the measured values, which resulted in 2-axis detuning ratios of -0.7 and -2.2%. The fabricated gyroscope showed a cross-axis sensitivity of +/-2.7%. The test results demonstrated that the gyroscope simultaneously detects yaw and roll rates with low cross-axis sensitivity.
Keywords :
gyroscopes; mass measurement; sensors; 2-axis detuning ratio; 2-axis yaw-and-roll gyroscope; single sensor element; synchronously-driven dual mass; Films; Frequency measurement; Gyroscopes; Joining processes; Resonant frequency; Sensitivity; Silicon; Gyroscope; cross-axis sensitivity; dual mass; roll; yaw;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), 2015 Transducers - 2015 18th International Conference on
Conference_Location :
Anchorage, AK
Type :
conf
DOI :
10.1109/TRANSDUCERS.2015.7181155
Filename :
7181155
Link To Document :
بازگشت