DocumentCode
731904
Title
Fabrication of microtip electrode array integrated with self-aligned reference electrode
Author
Bum-Ryul Maeng ; Seung-ki Lee ; Seoung-Jai Bai ; Jae-Hyoung Park
Author_Institution
Dept. of Electron. & Electr. Eng., Dankook Univ., Yongin, South Korea
fYear
2015
fDate
21-25 June 2015
Firstpage
1362
Lastpage
1365
Abstract
This paper presents a novel microtip-based electrode array with the reference electrode around tips. A microelectromechanical systems process for a microtip electrode array has been developed using DRIE and RIE combination process. The conductive microtip with high aspect ratio, small apex radius and the height of tens of micron scale is insulated except the tip ends. The tips are closely surrounded by the self-aligned reference electrode. The whole process was completed with a single photography mask. The fabricated microtip-based electrode array was successfully verified with the cyclic voltammetry measurements and characterized with the measurement of photosynthetic reaction of chlorella cell using microtip electrode array.
Keywords
masks; microelectrodes; microfabrication; micromechanical devices; sputter etching; voltammetry (chemical analysis); DRIE combination process; chlorella cell; conductive microtip; cyclic voltammetry measurements; microelectromechanical systems process; microtip-based electrode array; photosynthetic reaction measurement; self-aligned reference electrode; single photography mask; Arrays; Current measurement; Electrodes; Fabrication; Radiation detectors; Silicon; Cyclic voltammetry; Microtip electrode array; Photosynthetic reaction; Self-aligned reference electrode; Self-alignment;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), 2015 Transducers - 2015 18th International Conference on
Conference_Location
Anchorage, AK
Type
conf
DOI
10.1109/TRANSDUCERS.2015.7181185
Filename
7181185