Abstract :
The aim of this study is to present a phase compensation scheme that improves the accuracy of a power hardware-in-the-loop simulation. The ideal transformer model interface method along with feedback current filtering is used to connect a synchronous generator simulation to a test system. The generator is modeled using a voltage-behind-reactance representation. Comparison of experimental results against simulations confirms the validity of the proposal.
Keywords :
Active filters; Delays; Digital filters; Generators; Load modeling; Mathematical model; Synchronous machines; PHIL; phase compensation; prototype;