• DocumentCode
    735657
  • Title

    A shunt active compensation strategy with zero neutral current in two-phase three-wire systems

  • Author

    De S Furtado, Pablo C. ; Barbosa, Pedro G. ; Do C. B. P. Rodrigues, Marcio

  • Author_Institution
    Power Electron. & Autom. Group, Fed. Univ. of Juiz de Fora, Juiz de Fora, Brazil
  • fYear
    2015
  • fDate
    June 29 2015-July 2 2015
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This work deals with a shunt active power filter, which is controlled to compensate residential installations fed by two-phases and neutral derived from a three-phase grid. A compensation strategy is proposed to mitigate harmonic currents, reactive power and neutral currents due to reactive and nonlinear loads. System characteristics, the proposed control strategy and its implementation scheme are described in detail. Experimental results are presented in order to confirm the proposed two-phase three-wire compensation scheme.
  • Keywords
    active filters; compensation; electrical installation; power filters; power grids; power system harmonics; reactive power; control strategy; harmonic currents; neutral currents; nonlinear loads; reactive loads; reactive power; residential installations; shunt active compensation strategy; shunt active power filter; three-phase grid; two-phase three-wire compensation scheme; two-phase three-wire systems; zero neutral current; Harmonic analysis; Power electronics; Power quality; Power system harmonics; Reactive power; Shunts (electrical); Power conditioning; power quality; shunt compensation; two-phase active filters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    PowerTech, 2015 IEEE Eindhoven
  • Conference_Location
    Eindhoven
  • Type

    conf

  • DOI
    10.1109/PTC.2015.7232520
  • Filename
    7232520